Temperature controller Ascon Teconologic K85

Termoregolatore Ascon Tecnologic K85

ASCON TECNOLOGIC K85, REGULATOR MINI-PROGRAMMER FOR RAIL DIN, 3 RS485 OUTPUT:

  • Digital controller and mini-programmer with independent timers for DIN rail mounting
  • 4 DIN modules, 70 x 84 mm, depth 60 mm
  • IP40 front panel protection for indoor use
  • 1 red display 4 digit, h 12 mm + 3 LED bar graph
  • 1 input for temperature probes: tc J, K, S; infrared sensors J and K; RTD Pt 100 IEC; PTC KTY81-121 (990 Ω @ 25 ° C); NTC 103AT-2 (10K @ 25 ° C), for signals in mV 0 … 50 mV, 0 mV … 60, 12 … 60 mV or normalized signals 0/4 … 20 mA, 0. .1 V, 0/1 … 5 V, 0/2 … 10 V
  • 2 digital inputs for voltage-free contacts
  • Power supply: 24 VAC / VDC, 100 … 240 VAC / VDC ± 10%
  • Up to 3 relay outputs or voltage for driving SSR
  • Auxiliary power output: 12 VDC / 20 mA max
  • ON / OFF, ON / OFF Neutral Zone with time compressor protection, PID single and double action with overshoot control, Self-tune and control the doldrums (guaranteed soak)
  • Overall accuracy: ± 0.5% fs + 1 digit; tc S ± 1% fs + 1 digit
  • RS 485 isolated, MODBUS RTU (JBUS)
  • 1 Program 8 ramp and recovery segments, 2 events and control the doldrums
  • independent timers with 4 modes of operation
  • Wattmeter for the calculation of the instantaneous power consumed and energy

MECHANICAL PROPERTIES OF TEMPERATURE:

  • Housing: plastic, self-extinguishing UL 94 V0
  • installation: mounting on Omega DIN rail
  • Size: 70×84 mm (1/8 DIN), depth 98 mm
  • Display: Single Display, 4-digit, red, h 12 mm + 3 LED bar graph
  • weight: 180 g approx
  • Rear terminal block: 12 screw terminals (screw M3, for cables from 0.25 to 2.5 mm2 or from AWG 22 to AWG 14)
  • degree of protection: – front IP 65 protection in accordance with EN 60070-1 for indoor locations – Terminals: IP20
  • Input for TC, RTD, PTC, NTC, mA or V
  • user calibration
  • PID control H / C with overshoot control, self-tune and two algorithms autotuning
  • 8-segment programmer function with recovery segments, 2 events and control stasis (guaranteed soak)
  • independent timers with 4 modes of operation
  • On / OFF H / C with time compressor protection
  • Wattmeter for the calculation of the instantaneous power consumed and energy
  • Digital set point retransmission
  • Counter hours or days worked with programmable threshold for programmed maintenance
  • Function delay on power
  • Sequence programmable parameters
  • Ramps on set point change
  • Serial communication via RS485 with Modbus RTU protocol

This post is also available in: Italian

BL sistemi
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.